UPSSections
APC · US model
APC Back-UPS BE600M1: specifications and runtime
We review this exact model’s published ratings, runtime examples, outlet layout and shutdown documentation. Each figure carries a dated source.
Exact model identity: APC Back-UPS BE600M1, US 120 V model. Manufacturer identity source · checked 2026-10-17
Some links are affiliate links. BatteryRank may earn a commission at no extra cost to you.

Ratings, outlets and operating facts
Manufacturer-claimed specifications
Rated apparent power
600 VA. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/Rated real power
330 W. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/Topology
Standby · checked 2026-10-17On-battery waveform
Stepped approximation to a sinewave · checked 2026-10-17Transfer specification
6 typical / 10 max ms. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/Outlet split
5 battery + surge. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/2 surge-only. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/7 total. Show source
claimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/Model-specific check
This standby model has a lower watt ceiling than the larger line-interactive UPS choices in this pilot. Use its battery-backed outlet group for the equipment that must stay on, and compare the device’s stated power quality needs with the sourced stepped-approximation waveform. Its charging receptacle and PowerChute data connection are separate.
APC product source · checked 2026-10-17APC manual · checked 2026-10-17Manufacturer runtime examples
Each point is the manufacturer’s stated runtime at its listed output load and test condition. These examples are not extrapolated into estimates for other loads.
| Load condition | Reported runtime | Source |
|---|---|---|
330 W. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/ | 3 min 12 sec. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-600va-120v-1-usb-charging-port-7-nema-outlets-2-surge/ | Manufacturer runtime · checked 2026-10-17At the manufacturer page’s 100% capacity-used setting; page load range 33–330 W. |
Use the linked manufacturer chart for loads not listed here. We do not infer runtime from VA, watt-hours, battery Ah or an unlisted load.
Communication and shutdown support
Data connection
Separate USB Type-A smart charging port and USB data port for PowerChute communication; the charging receptacle is not the data connection.
Source checked 2026-10-17Shutdown limits
The model manual describes a USB data connection and PowerChute Personal Edition for saving open files and shutting down a Windows computer during an outage. It does not establish NAS compatibility.
Source checked 2026-10-17Confirm your exact operating system or NAS model with both manufacturers. A USB connector alone does not establish software or protocol compatibility.
Read the model in context
The BE600M1 is a standby UPS rated for 330 W and 600 VA, with five battery-backed outlets and two surge-only outlets. The manufacturer specifies a stepped approximation to a sinewave on battery and 6 ms typical / 10 ms maximum transfer. Compare the connected equipment’s actual real-power and apparent-power demand against both ratings, and keep devices needing outage power on the five battery-backed receptacles.
The USB Type-A receptacle provides smart charging; a separate USB data port connects to PowerChute. The manual describes Windows computer monitoring and shutdown. It does not establish compatibility with a NAS or another host operating system.
The listed runtime point is at the manufacturer page’s maximum-load setting. For a router or other low-load device, use the exact model’s source chart at the measured load; this desktop-load point does not support a low-load runtime estimate.
APC product specifications · checked 2026-10-17 BE600M1 manual · checked 2026-10-17