Exact model identity: APC Back-UPS Pro BR1500MS2, US 120 V model. Manufacturer identity source · checked 2026-10-17

Check current Amazon offer

Some links are affiliate links. BatteryRank may earn a commission at no extra cost to you.

APC Back-UPS Pro BR1500MS2 tower uninterruptible power supply, manufacturer product photo
Manufacturer product image · checked 2026-10-17

Ratings, outlets and operating facts

Manufacturer-claimed specifications

Rated apparent power

1500 VA. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/

Rated real power

900 W. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/

Topology

Line-interactive · checked 2026-10-17

On-battery waveform

Sine wave on battery · checked 2026-10-17

Transfer specification

8 typical / 10 max ms. Show sourceclaimed sourceiportal2.schneider-electric.comchecked 2026-10-17https://iportal2.schneider-electric.com/Contents/docs/BR1500MS2_User%20guide.pdf

Outlet split

6 battery + surge. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/
4 surge-only. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/
10 total. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/

Model-specific check

The front Type-A and Type-C receptacles are charging ports. UPS status and shutdown use the separate communication port; APC’s manual documents PowerChute Personal Edition for Windows and does not establish NAS compatibility. Verify the host software path before buying for graceful shutdown.

APC manual · checked 2026-10-17

Manufacturer runtime examples

Each point is the manufacturer’s stated runtime at its listed output load and test condition. These examples are not extrapolated into estimates for other loads.

APC Back-UPS Pro BR1500MS2 manufacturer runtime points
Load conditionReported runtimeSource
900 W. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/
3 min 12 sec. Show sourceclaimed sourceshop.se.comchecked 2026-10-17https://shop.se.com/pro/us/en/product/apc-back-ups-pro-1500va-900w-tower-120v-10x-nema-5-15r-outlets-avr-usb-type-a-c-ports-lcd-user-replaceable-battery/
Manufacturer runtime · checked 2026-10-17At the manufacturer page’s 100% capacity-used setting; page load range 90–900 W.

Use the linked manufacturer chart for loads not listed here. We do not infer runtime from VA, watt-hours, battery Ah or an unlisted load.

Communication and shutdown support

Data connection

Separate USB/serial data port for UPS communication; the front USB Type-A and Type-C ports are charging-only.

Source checked 2026-10-17

Shutdown limits

The manual directs users to connect the supplied USB communication cable to the data port for PowerChute Personal Edition. The manual documents Windows support; it does not establish NAS compatibility.

Source checked 2026-10-17

Confirm your exact operating system or NAS model with both manufacturers. A USB connector alone does not establish software or protocol compatibility.

Read the model in context

The watt rating is the real-power ceiling, while the VA rating is a separate apparent-power limit. Compare both with the computer, display and network equipment, and connect high-priority gear to the battery-backed outlets shown above. The surge-only outlets do not continue running when mains power fails.

APC’s runtime point is tied to the manufacturer page’s maximum-load setting. It cannot be stretched into an estimate for another desktop or NAS load; use the source chart and the actual measured draw for planning.