← All use cases

Calculated scenario · sourced manifest

Power a Refrigerator, Wi-Fi, and Lights

18 stations pass every configured check; 61 fail at least one.

Energy per day
2,160 Wh
Sourced manifest ↓
Running load
234 W
Sourced manifest ↓
Worst-start surge
1,254 W
Sourced manifest ↓
Required delivered energy
2,160 Wh
Sourced manifest ↓
Stations passing
18
Sourced manifest ↓
Stations failing
61
Sourced manifest ↓
Edit this plan in the sizing tool →

01 · Load manifest

Every load in the calculation

Average draw applies each sourced duty cycle; energy is average draw × quantity × daily hours × scenario days.

Sourced device loads and calculated energy
DeviceQuantityHours / dayAverage drawScenario energySource
Refrigerator (full-size)AC12463 W1,512 WhSource · 2026-07-06
Wi-Fi router + modemAC12418 W432 WhSource · 2026-07-06
LED lamp (60W-equivalent bulb)AC469 W216 WhSource · 2026-07-06

02 · Station picks

Three ways to cover the plan

Some links on this page are affiliate links. BatteryRank may earn a commission at no extra cost to you. Commission never affects whether a station passes these checks; when two stations tie on every measured criterion, the one with a live retail offer is shown.

Critical-load fit

Pecron F5000LFP

Projected runtime
1.8 days
Headroom
81.3%
Weight
56.2 kg

Why it fits

6,966 W above the plan's running load (7,200 W continuous output)

Main compromise

4,800 W below the highest output reserve across 18 eligible models

Open sourced model dossier →

Best all-round fit

EcoFlow DELTA Pro 3

Projected runtime
1.8 days
Headroom
75.5%
Weight
51.5 kg

Why it fits

75.6 BatteryRank score — the highest of any station that fits this plan

Main compromise

4 points below the highest-scoring eligible model across 18 eligible models

Open sourced model dossier →

Maximum useful reserve

Zendure SuperBase V6400

Projected runtime
2.3 days
Headroom
128%
Weight
Not sourced

Why it fits

2.3 projected runtime days

Main compromise

2.6 days less projected runtime than the longest-running eligible model across 18 eligible models

Open sourced model dossier →

Solar balance

What recharging changes

The default plan does not assume solar recharging. Add a panel size in the editable calculator to see daily harvest and deficit by station.

Review the published solar method →

Explore passing models by projected runtime

This ordered data view is separate from the three recommended buying strategies above.

  1. 01EcoFlow DELTA Pro Ultra X4.8 days
  2. 02EcoFlow DELTA Pro Ultra2.4 days
  3. 03Zendure SuperBase V64002.3 days
  4. 04Jackery Explorer 5000 Plus2 days
  5. 05Pecron F5000LFP1.8 days

Questions from the same calculation

How much power do you need for a refrigerator, Wi-Fi, and lights?
2,160 Wh of delivered energy over 1 day, drawing 234 W if every device runs at once. Refrigerator (full-size) alone is 70% of that energy, so it is the load worth measuring first — the rest of the manifest barely moves the answer.
What decides whether a station can start this setup?
Refrigerator (full-size). Its sourced 1,200 W startup demand, arriving while the other devices keep running, sets a worst-case moment of 1,254 W — well above the 234 W running total. A station sized only to the running figure will carry this plan right up until that device restarts.
Why is every load on this plan running through the inverter?
None of the devices in this manifest has a manufacturer-supported DC input, so each one pays the DC-to-AC conversion cost. Where a device does offer a native 12 V cord — camping fridges especially — using it is the cheapest runtime you can buy.