Solar panelsSections
Sourced compatibility · 15 stations · 10 panels
Which solar panels fit your power station?
Compare manufacturer panel ratings with exact EcoFlow, Jackery, BLUETTI and Anker SOLIX solar inputs. The checker uses sourced Voc, Vmp, Isc and rated power; it leaves unverified fields and wiring arrangements unknown.

Check your setup
Choose an exact power station and panel. The results compare published electrical ratings. Confirm the cable, polarity and cold-weather voltage in the source documents before connecting.
Within listed limits
Solar input · EcoFlow
Input checked: 11–60V · 15A · 500W
Published Vmp, Voc, Isc and power are within the 11–60V/15A/500W input. This is a nominal check. Confirm cold-weather Voc, cables and polarity before connecting.
Station limits: 11–60V solar input · 15A max · 500W max
Station connector: Solar/Car port; solar-to-XT60/XT60i cable (sold separately)
- Voc
- 25.9V
- Vmp
- 21.6V
- Isc
- 4.86A
- Rated power
- 100W
Panel connector: MC4
- DELTA 2 online manual · checked 2026-10-12
- Anker SOLIX Bifacial Portable Solar Panel Datasheet, 2025-11-07 (manufacturer-authored PDF mirrored by Device.report) · checked 2026-10-09
How to read the check
Voltage, current, power and wiring
Vmp must meet the selected station input’s minimum. Voc must stay below its maximum, and Isc is checked against the published current ceiling. Rated watts above an input cap are limited to that port’s listed maximum. For two panels in series, Voc and Vmp add; in parallel, Isc adds. Jackery’s combined two-port limit is applied only to its documented two-panel parallel arrangement.
These are nominal STC screens, not connection approvals. Panel Voc can rise in cold conditions, and bifacial rear illumination can raise current. Confirm cold-weather Voc, the exact station port, polarity, fuses, cables and the station’s permitted wiring before connecting. An unknown Vmp or undocumented array layout stays unknown.
The checker displays station and panel connector types but does not infer adapter compatibility from plug shape. Read the linked OEM documents for the cable supplied with your exact revision.
Station evidence
Solar input limits by exact model
Input values and connector descriptions come from the linked manufacturer manuals and product specifications checked 2026-10-12. A cable connector remains marked unknown where the OEM source does not identify it.
EcoFlow RIVER 2
1 solar input · DC input port; EcoFlow solar charging cable
- Minimum operating input
- 11V
- Maximum Voc
- 30V
- Maximum input
- 110W
- Current ceiling
- 8A
- RIVER 2 online manual · checked 2026-10-12
EcoFlow RIVER 2 Max
1 solar input · DC input port; parallel connection cable in package list
- Minimum operating input
- 11V
- Maximum Voc
- 50V
- Maximum input
- 220W
- Current ceiling
- 13A
- RIVER 2 Max online manual · checked 2026-10-12
EcoFlow RIVER 2 Pro
1 solar input · DC input port; parallel connection cable in package list
- Minimum operating input
- 11V
- Maximum Voc
- 50V
- Maximum input
- 220W
- Current ceiling
- 13A
- RIVER 2 Pro online manual · checked 2026-10-12
EcoFlow RIVER 3
1 solar input · Solar/Car port; solar-to-XT60i cable (sold separately)
The exact-model manual (EFR705) specifies 110W/30V/8A; the Shopify base page mirrors Plus-class 220W content and is not used.
- Minimum operating input
- 11V
- Maximum Voc
- 30V
- Maximum input
- 110W
- Current ceiling
- 8A
- RIVER 3 online manual (exact model EFR705) · checked 2026-10-12
EcoFlow RIVER 3 Plus
1 solar input · Solar/Car port; solar-to-XT60i cable (sold separately)
- Minimum operating input
- 11V
- Maximum Voc
- 55V
- Maximum input
- 220W
- Current ceiling
- 13A
- RIVER 3 Plus online manual · checked 2026-10-12
EcoFlow DELTA 2
1 solar input · Solar/Car port; solar-to-XT60/XT60i cable (sold separately)
- Minimum operating input
- 11V
- Maximum Voc
- 60V
- Maximum input
- 500W
- Current ceiling
- 15A
- DELTA 2 online manual · checked 2026-10-12
EcoFlow DELTA 2 Max
2 solar inputs · Two solar ports; 500W each; solar-to-XT60/XT60i cable (sold separately)
Limits apply per port; 1,000W is the dual-port total.
- Minimum operating input
- 11V
- Maximum Voc
- 60V
- Maximum input
- 1000W
- Current ceiling
- 15A
- DELTA 2 Max online manual · checked 2026-10-12
EcoFlow DELTA 3
1 solar input · XT60 solar port; solar-to-XT60i cable (sold separately); parallel cable in package list
- Minimum operating input
- 11V
- Maximum Voc
- 60V
- Maximum input
- 500W
- Current ceiling
- 15A
- DELTA 3 online manual · checked 2026-10-12
EcoFlow DELTA 3 Plus
2 solar inputs · Two XT60 ports; 500W each; solar-to-XT60i cable (sold separately)
Limits apply per port; 1,000W is the dual-port total.
- Minimum operating input
- 11V
- Maximum Voc
- 60V
- Maximum input
- 1000W
- Current ceiling
- 15A
- DELTA 3 Plus online manual · checked 2026-10-12
EcoFlow DELTA Mini
1 solar input · Solar/Car port; solar-to-XT60i cable (sold separately)
Conservative 10A from the current product page; the manual PDF states 13A. The lower figure governs this matrix.
- Minimum operating input
- 11V
- Maximum Voc
- 75V
- Maximum input
- 300W
- Current ceiling
- 10A
- DELTA Mini user manual (PDF) · checked 2026-10-12
- Official product specifications · checked 2026-10-12
EcoFlow DELTA Pro
1 solar input · Solar/Car port; solar-to-XT60/XT60i cable (sold separately)
- Minimum operating input
- 11V
- Maximum Voc
- 150V
- Maximum input
- 1600W
- Current ceiling
- 15A
- DELTA Pro online manual · checked 2026-10-12
EcoFlow DELTA Pro 3
2 solar inputs · High-PV XT60 (30–150V/15A/1600W) + Low-PV XT60i (11–60V/20A/1000W)
Two dissimilar ports: series totals must respect the chosen port’s Vmax; parallel totals should sit close to its Imax.
- Minimum operating input
- 11V
- Maximum Voc
- 150V
- Maximum input
- 2600W
- Current ceiling
- 20A
- DELTA Pro 3 online manual · checked 2026-10-12
Jackery Explorer 1000 v2
2 solar inputs · 2 × DC8020 solar input ports; 200W and 10.5A max per port, 400W and 21A max across both ports.
The 400W/21A rating is the two-port total. Each DC8020 port is limited to 200W/10.5A.
Jackery documents its two DC8020 solar inputs as parallel and requires simultaneous panels to have the same wattage. This checker repeats the selected panel model at both inputs; the reviewed sources do not confirm a series pair.
- Minimum operating input
- 16V
- Maximum Voc
- 60V
- Maximum input
- 400W
- Current ceiling
- 21A
Per port: 16–60V · 10.5A · 200W; two-panel parallel total: 400W / 21A
- Jackery Explorer 1000 v2 User Manual · checked 2026-10-12
- Explorer 1000 V2 Basic Information · checked 2026-10-12
BLUETTI AC180
1 solar input · BLUETTI solar charging cable; the reviewed manual does not name the station-side plug geometry.
Use the BLUETTI solar charging cable. Confirm its supplied station-end connector and polarity for the exact unit.
The AC180 manual permits panels in series or parallel, provided the resulting array stays within the listed Voc, current and power limits.
- Minimum operating input
- 12V
- Maximum Voc
- 60V
- Maximum input
- 500W
- Current ceiling
- 10A
- BLUETTI AC180 User Manual · checked 2026-10-12
- BLUETTI AC180 U.S. product specifications · checked 2026-10-12
Anker SOLIX C1000 Gen 2
1 solar input · XT60i input; Anker’s guide identifies a solar charging connection to the XT60i port.
Input current is 8.2A at 11–28V and 14.5A at 29–60V; the separate array Isc ceiling is 15A.
For multiple panels, Anker specifies parallel wiring and a combined array Voc no higher than 60V and Isc no higher than 15A. Series wiring is not supported by the reviewed guide.
- Minimum operating input
- 11V
- Maximum Voc
- 60V
- Maximum input
- 600W
- Current ceiling
- 14.5A · 15A Isc cap
- Anker SOLIX C1000 Gen 2 User Guide (B1763) · checked 2026-10-12
- Anker SOLIX C1000 Gen 2 U.S. product specifications · checked 2026-10-12
Panel evidence
Electrical ratings and connectors
Each rating links to the OEM source and checked date used in the calculation. “Not published” means we did not find that value in the reviewed manufacturer record; the checker will not fill it in.